Apr 17, 2014· Excel, for example, is a powerful spreadsheet with VBA robust programming capabilities that can be a powerful tool for teaching civil engineering concepts. Spreadsheets can do basic calculations such as cost estimates, schedule and cost control, and markup estimation, as well as structural calculations of reactions, stresses, strains ...

Footings Example 1—Design of a square spread footing of a seven-story building Design and detail a typical square spread footing of a six bay by five bay seven-story building, founded on stiff soil, supporting a 24 in. square column. The building has a 10 ft high basement. The bottom of the footing is 13 ft .

Size of fillet welds (Outside and reinforcing pad fillet-if required) Furthermore you will be able to: ... This Calculation Method excludes the following: Piping systems designed for internal gage pressures at or above zero but less than 15 psi (103 kP) provided the fluid handled is nonflammable, nontoxic, and not damaging to human tissue as ...

The required width of a reinforcement pad is calculated for a defined pad thickness. The reinforcement pad thickness should be adjusted so that the entire pad with is inside the reinforcement zone (the actual pad width is the pad width inside the reinforcement zone). Welds and collars etc can be accounted for as an equivalent pad width provided ...

Jul 27, 2015· Pipe branch reinforcement calculations per ASME B31. The user can choose pipe materials, flange rating and material, pipe dimensions, factors, .

Calculation of Pipe Reinforcement ASME B31.3 - Free download as Excel Spreadsheet (.xls), PDF File (.pdf), Text File (.txt) or read online for free. Hi Everybody, Here is a spreadsheet for Reinforcement Pad Thickness Calculation per ASME B31.3. Pressure Design Run Pipe and Branch Pipe. File is attached herewith. Best Regards Ajay Sharma

BRANCH REINFORCEMENT PAD REQUIREMENT CALCULATION - Free download as Excel Spreadsheet (.xls), PDF File (.pdf), Text File (.txt) or read online for free.

Apr 26, 2007· Is there any excel reinforcement calculation available for welded branches according to ASME B31.8? I've been assigned to perform a reinforcing area calculation for internal pressure of a 2" XS weldolet SA 350 LF2, welded to a 20" header API 5L X65 t=11,9mm. Thanks in advance.

ExcelCalcs is a community who share an interest in making calculations with MS Excel. Use our XLC add-in for Excel to display cell formulas as easily readable mathematical equations. Downloading worked solutions from our Repository gives you a head start in solving technical problems.

Simplified Calculations for Reinforcement of Openings (Fig. 2.12) To determine whether an opening is adequately reinforced, it is first necessary to determine whether the areas of reinforcement available will be sufficient without the use of a pad.

This calculation steps simplifies the reinforcement calculation. The calculation result suggests that there is no need for providing reinforcement pad and hence self reinforced nozzle is used. If condition is Ar> Atotal than only additional reinforcement would be required. VII.

This spreadsheet consists of many segments regarding RCC aspects as described below: Beam Design (Flexural design, Serviceability, Shear desi...

Calculation of PipeReinforcement ASMEB31.1.xls. caesar ii training. Trunnion Calc r6 ... BRANCH REINFORCEMENT PER ASME B31.4 PIPELINE. Branch Reinforcement for CS pipe. Support Calculation. Nozzle Reinforcing Calculations for a Pressure Vessel Design - By Abdel Halim Galala ... Documents Similar To Calculation for Reinforced Pad. Carousel ...

3/11/2012, ReinfS1.xls Pipe Branch Reinforcement Page 2 of 2 per ASME B31.1 -2010 Power Piping Code Branch (1) Calculations Nom. thk. of pad: tnr = 0.322 in. = 8.18 mm Width of pad from edge of branch: wr = 0.875 in. = 22.23 mm Height of saddle above run: hs = n/a - - .

Reinforcement Area Provided As = Spacing Bar Option No. of Bars Selected Longitudinal Bars: Development Length Calculations: λ = ψt = ψe = ψs = c = Ktr = (lightweight aggregate factor) (reinforcement location factor) (coating factor) (reinforcement size factor) spacing/cover dimension (transverse reinf. Index) Transverse Reinf. Factor c ...

May 24, 2016· This Video explain about To Fabricate the Reinforcing Pad for saddle'T'.From this Excel calculation sheet, you can find the data very quickly and accurately. Buy now just 1$ USD (Rs.70) click ...

Area provided by deposited weld metal beyond the outside diameter of the run & branch, mm 2. Area provided by a reinforcing ring, pad or integral reinforcement, mm2. Area provided by a saddle on right angle connection, mm2. Outside diameter of reinforcement ring, mm. Stress value for reinforcement ring material, N/mm2.

May 30, 2014· Good morning, i m calculating reinforcing pad (added reinforcing area A4 as per ASME B31.3 appendix H example 2) but i have not find any formula for it.(in ring and in fillet welds) also in this example tc/0.707=0.250/0.707 =0.354 define "tc". In 304.3.2 they are refering 304.3.2(f) after that refering to 328.5.4 which also refers to 300.2 and i have not find any formula for it.

Oct 14, 2019· Formula (d^2/162) for calculation of per metre weight of rebar derived Companies offer Best Civil Engineering Opportunities in India List of Some Useful IS Codes for Civil Construction Work Wailk In Interviews 12th -14th Oct, 2016 in Shapoorji Pallonji Co. Ltd

In this paper, design calculation of nozzle junction based on ASME pressure vessel design code is carried out for nozzle to head junction subjected to applied external load, internal pressure and ...

calculation steps simplifies the reinforcement calculation. The calculation result suggests that there is no need for providing reinforcement pad and hence self reinforced nozzle is used.

Oct 14, 2019· Analysis of Rates of Building Construction in Excel. Units Calculator Excel Sheet for Conversion of Measurement. Requirement of Material and Labour for Civil Work. Cost Estimation RCC Building Excel Sheet. Calculation of Brick Masonry Estimating Quantity Excel Sheet. Calculation of Cement and Sand for Plastering Excel Sheet. Design of Doubly ...

2. Internal Stability (deals with soil reinforcement) a. Reinforcement Pullout (pullout from reinforced soil mass) b. Reinforcement Strength (tension rupture) c. Reinforcing to Facing Connection The weight and dimensions of the wall facing elements are typically ignored for both external and internal stability calculations.

Nov 21, 2016· Yes, i will try to anwer with assume the size myself * Calculate steel quantity for slab * * example we will make concrete slab with dimension 4m x 8m, with tickness 12 cm, steel to used 100–200 (its means steel with diametre 100 cm with space 20...
WhatsApp)